To ensure that the sensitivity level of the monitors is correct for your baby`s mattress carry out the following Four Corner Test for your AC027 model:
PLEASE NOTE:
Your baby must NOT be in the cot during this test:
Sources of vibration & movement other than your baby’s can be detected by the Sensor Pad and interfere with the performance of your Angelcare monitor. The alarm will not sound if it detects movement other than your baby’s
There are 3 sensitivity settings – low, medium and high. The unit is set at medium (default) and can be adjusted accordingly
The Sensor Pad will detect your movements if you are touching the cot
The monitor will produce a Rouse alarm single beep tone designed to stir baby if no movement has been detected for 15 seconds.
If no movement is detected after a further 5 seconds, the main alarm will sound – this is a series of continuous beeps
To check that the sensitivity is correct for your baby`s mattress see the following Four Corner Test:
Place the Sensor Pad at the approximate centre of baby’s sleeping area and put the mattress back in place
Switch ON the Nursery Unit – check that Nursery Unit and Sensor Pad are paired (connected)
Immediately pat your hand lightly and continuously on a corner of the mattress twice for Sensor to detect movement
Step away from the cot
The alarm will sound from the Nursery and Parent Unit after 20 seconds
If the Alarm does not sound, ensure everything is setup correctly and repeat the above again; check battery levels on all units, follow the manual for ‘NO ALARMS’ – the sensitivity setting may require lowering by a single level due to other vibrations/movements
If the alarm sounds, pat your hand lightly on a corner of mattress twice for Sensor to detect movement. It may take up to 8 seconds to recognise movement and for alarm to stop
If the alarm continues, even after lightly patting the corner of your mattress twice, adjust the sensitivity higher and repeat this test
Comments
0 comments